Honeywell Primary Controls Cross Reference Guide – Great Prices Burner Controls, Relays, Flame Safety

Honeywell Temperature Controls Cross Reference Guide  Burner Controls, Relays, Flame SafetyHoneywell Primary Controls Cross Reference Guide – Great Prices Burner Controls, Relays, Flame Safety

 

 

Ordering Guide (PDF)

 

 

We ship these products worldwide! Delivery is normally stock.

Request a Quote now or call us at 1-800-755-2883 for expert assistance.

 

 

 

 

 

 

 

Device To Be ReplacedCurrent
Replacement
7800 Series
Replace-
ment     
Wiring Number NumberComments
R177ARA890F 1
RM7890A1015power—1,2 limit—1-5 motor—3 ignition—4 controller—R,W,B detector—F,GRemove Series 10 Controller and rewire.
Same as RA890F except does not have “proof of flame” terminal (terminal 5 on RA890E,F).
Requires Q270A Subbase with RA890F.
Requires Q7800F1004 Subbase with RM7890A1015.
R180ARA890F 1
RM7890A1015power—1,2 jumper—1-3
limit, main valve—4 controller—R,W,B detector—F,G
Continuous pilot applications only. Remove Series 10 Controller and rewire. Requires Q270A Subbase with RA 890F.
Requires Q7800F1004 Subbase with RM7890A1015.
R180BRA890F 1
RM7890A1015power -1,2
limit, main valve—5 motor, pilot valve—3 ignition—4 controller—R,W,B detector—F,G
Functionality same as RA890F.
Remove Series 10 Controller and rewire. Requires Q270A Subbase with RA890F.
Requires Q7800F1004 Subbase with RM7890A1015.
R187ARA890F 1
RM7890A10105power—1,2 limit—1-5 motor—3 ignition—4 controller—R,W,B detector—F,GRemove Series 10 Controller and rewire. Requires Q270A Subbase with RA890F.
Requires Q7800F1004 Subbase with RM7890A1015.
R190B, RA190BRA890F 1
RM7890A1015See 180BRemove Series 10 Controller and rewire. Requires Q270A Subbase with RA890F.
Requires Q7800F1004 Subbase with RM7890A1015.
R190CR4138C,D RA890H 4
RM7838A,B RM7890B1014See Modernization Wiring Information section.Used in W124 and ID051 panels.
See Modernization Wiring Information section.
R887ARA890F 1
RM7890A1015power—1,2 limit—1-5 motor—3 ignition—4 controller—T,T detector—F,GRewire.
Requires Q270A Subbase with RA89OF.
Requires Q7800f1004 Subbase with RM7890A1015.
R890B, RA890BRA890F 1
RM7890A1015power—1,2 limit—1
motor,pilot valve—3 ignition—4
main valve—5 controller—6 jumper—T,T detector—F,G
Requires Q7800F1004 Subbase with RM7890A1015.
R890C, RA890CRA890F 1
RM7890A1015Same as R890B, RA890BRequires Q7800Fl004 Subbase with RM7890A1015.
RA890XB RA890XCRA890F 1
RM7890A1015Same as R890B, RA890BRequires Q7800F1004 Subbase with RM7890A1015.
RA890DR4140M 1
RM7840M1017Same as R890B, RA890B except controller always on terminal 6 and LF switch to T,TRequires Q520A Subbase and R7247A Amplifier with R4140M.
Requires Q7800L1001 Subbase and R7847A1009 or R7847B1007 Amplifier with RM7840M1017.

 

SpecificationsCurrent
Rplcmt.
SERIES 7800
Replacement
RA890H,J,K
OS Number to be
Replaced 6        7
Voltage
(50/60)
RA890H1011208NoneNone
RA890H1029240NoneNone
RA890H1037100NoneNone
RA890H1045220NoneNone
RA890H1052120H1052RM7890A1015
RA890J1008120J1008None
RA890J1016120J1008None
RA890J1024208NoneNone
RA890J1032240NoneNone
RA890K1006120H1052RM7890A1015

 

Device To Be Replaced
R4075A1009
Current
Replace-
ment     
NONE
SERIES
7800
Replace-
ment     
NONE
R4075A1025NONENONE
R4075A1033
R4075A1041
NONE
NONE
NONE
NONE
R4075A1058
R4075B1007
R4075B1015
R4075B1023
R4075B1031
R4075B1049
R4075B1056
R4075C1005
R4075C1013
R4075C1021
R4075C1039
R4075D1003
R4075E1000
R4075E1018
NONE R4075C1005 7
R4075C1005 7
R4075C1005 8
R4075C1005 7
R4075C1005 8
R4075C1005
R4075C1005
R4075C1013
R4075C1021
R4075C1039
R4075D1003
R4075E1000
NONE
NONE RM7885A1015 6
RM7885A1015 6
RM7885A1007 13
RM7885A1015 6
RM7885A1007 13
RM7885A1015 6
RM7885A1015 6
NONE NONE NONE
RM7885A1015
6
NONE NONE

 

R4795A1099
R4795A1107
R4795C1004
R4795D1002
R4795D1010
R4795D1028
R4795D1036
R4795D1044
R4795D1051
R4795D1069
R4795A1099
R4795A1107
R4795A1016 2
R4795D1002
R4795A1002
None None None
R4795D1051
R4795D1069
None
None
RM7895A1014
RM7895B1013
RM7895C1012
RM7895D1011
RM7895A1014
RM7895B1013
RM7895C1012
RM7895D1011
RM7895A1014RM7895B1013
RM7895C1012
RM7895D1011
None None None
RM7895A1014RM7895B1013
RM7895C1012
RM7895D1011
None

 

Device to be Replaced R7023A1005   Current       Replacement     R7023B1003Series 7800
Replacement
RM7823A1016
R7023A1021R7023B1052None
R7023A1039R7023B1011None
R7023A1047R7023B1003 5
RM7823A1016
R7023A1054NoneNone
R7023A1062R7023B1052 5
None
R7023A1070R7023B1037None
R7023B1003R7023B1003RM7823A1016
R7023B1011R7023B1011None
R7023B1029NoneNone
R7023B1037R7023B1037None
R7023B1045R7023B1003 5
RM7823A1016
R7023B1052R7023B1052None
R7023B1060
R7023C1001
R7023B1052 5
R7023C1001
NoneE RM7823A1016
R7023C1019R7023C1019RM7823A1016
R7023C1027R7023C1027None
R7023C1035R7023C1035None
R7023C1043R7023C1050 6
None
R7023C1050
R7023C1068
R7023C1050
None
None
RM7823A1016
R7023X1002NoneNone
R7023X1010
R7023X1028
None
R7023B1052
None
None
R7023X1036R7023B1052 5
None
R7023X1044R7023B1052None
R7023X1051
R7023X1069
R7023X1077
R7023X1085
R7023X1093
R7023B1052 5
R7023B1052 5     7
None
R7023B1052
5     7
R7023C1027
None None None None None